We were the Engineer of Record for a product only recovery system on contaminated commercial land across the street from a former fuel retail site in British Columbia, Canada.
McCue designed a recovery system for free phase gasoline product. The design met the fire code, and site owner safety and material specification requirements. The system incorporates five in well product only pumps, dedicated compressed air and waste discharge lines, two containment sumps containing all the buried fittings, and the equipment, which is equipped with telemetry for remote operation.
McCue prepared a design package that included:
- Design drawings for construction
- Design failure analysis
- As-built drawings and related documentation
- The operation and maintenance (O&M) manual